Constant voltage mode power supply
Universal AC input / Full range 

Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Over current / Over voltage

Cooling by free air convection

Fully encapsulated with IP67 level (Note.8)

Fully isolated plastic case

Suitable for LED lighting and moving sign applications

100% full load burn-in test

Low cost, high reliability
2 years warranty

Specification

 

MODEL LPV-100-12
OUTPUT DC VOLTAGE 12V
CURRENT RANGE 0 ~ 8.5A
RATED CURRENT 8.5A
RATED POWER 102W
RIPPLE & NOISE (max.)  Note.2 120mVp-p
VOLTAGE TOLERANCE  Note.3 ±5.00%
LINE REGULATION ±1.00%
LOAD REGULATION ±2.00%
SETUP, RISE TIME NOTE.6 2000ms, 25ms / 230VAC 2000ms, 25ms / 115VAC at full load
HOLD UP TIME (Typ.) 50ms/230VAC 14ms/115VAC at full load
INPUT VOLTAGE RANGE 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 85%
AC CURRENT (Typ.) 2.2A/115VAC 1.2A/230VAC
INRUSH CURRENT (Typ.) COLD START 75A/230VAC
LEAKAGE CURRENT 0.25mA / 240VAC
PROTECTION OVER CURRENT 110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE 13.8 ~ 16.2V
Protection type : Shut down O/P Voltage,re-power on to recover
ENVIRONMENT WORKING TEMP. -25 ~ + 70°C (Refer to output load derating curve)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +80°C , 10 ~ 95% RH
TEMP. COEFFICIENT ± 0.03%/°C (0 ~ 50°C )
VIBRATION 10 ~ 500Hz, 2G 12min./1cycle, period for? 60min. each along X, Y, Z axes
SAFETY &EMC(Note 4) SAFETY STANDARDS IP67 approved;design refer to TUV EN60950-1
WITHSTAND VOLTAGE? I/P-O/P:3KVAC
ISOLATION RESISTANCE I/P-O/P:>100M Ohms /500VDC/ 25°C/70% RH
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT Compliance to EN61000-3-2 Class A,EN61000-3-3
EMS  Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
IMMUNITY
OTHERS MTBF 703Khrs min. MIL-HDBK-217F (25 )
DIMENSION 190*52*37mm (L*W*H)
PACKING 0.63Kg; 20pcs/13.6Kg/0.51CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.

7.The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the plssible use of the unit.

8.Suitable for indoor use or outdoor use without direct sunlight exposure,Please avoid immerse in the water over 30 minute.

 